Description

Y8610F5003 features continuous trial for pilot ignition with no shut down or lock out. This unit typically uses for VR8204, VR8304 gas control, and it comes with complete kit converting conventional standing pilot system to intermittent pilot system.

Specifications

  • Ignition System Type: Intermittent Pilot
  • Ignition Sequence: Continuous trial for pilot ignition [no shut down or lockout]
  • Typical Gas Control: VR8204, VR8304
  • Type of Gas: Natural
  • Flame Sense: Single Rod
  • Ignition Source: Internal high voltage spark generator
  • PrePurge: None
  • Typical Ignition Hardware: Q345, Q3451
  • Dimensions: 3 15/16"H x 5 7/16" W x 2 5/8" D
  • Dimensions: 100 mm H x 138 mm W x 67 mm D
  • Electrical Ratings: 24 Vac/60 Hz
  • Maximum Ambient Temperature: 0 F to 165 F/-18 C to +74 C
  • Flame Failure Response Time: 0.8 sec. @ 1.0 micro-amp